DR system, namely direct digital X-ray photography system, is composed of electronic cassette, scanning controller, system controller, image monitor, etc., which directly converts X-ray photons into digital images through electronic cassette, and is a kind of direct digital X-ray photography in a broad sense.In the narrow sense, direct digital photography, namely DDR, usually refers to digital Radiography with the technology of direct image conversion using flat panel detector, which is a direct digital X-ray photography system in the true sense.According to the detector type, it is mainly divided into amorphous silicon plate DR(main stream), amorphous selenium plate DR and CCD DR(main stream).According to the frame structure, it is divided into hanging DR and UC arm DR.

The NKX-502 Sickle-arm DR machine produced by Shandong Huarai Imaging is mainly used for the photographic examination of human chest, limbs, pelvis and lumbar spine.

 

Product Advantages:

1, microcomputer control, LIQUID crystal display, easy to operate.

2. New design of high frequency and high voltage generator

3. Stable and accurate exposure conditions can reduce the production of soft rays while reducing radiation dose, effectively protecting patients and doctors.

4, simple and convenient position display, according to the selection of patient body shape, location, automatic exposure parameters, and can be saved and modified.New sickle arm design

5. Accurate rotation Angle and multi-angle photography can meet clinical requirements.

6. Reassuring security features

Fault self-diagnosis function can quickly and accurately determine the fault status, and can automatically protect, display fault code, accurate and convenient in time.7. Adopting digital plate detector, the performance is stable and the X-ray dose is greatly reduced

Main configuration and parameters:

  1. X-ray high frequency and high voltage generator

 

  1. Power supply voltage: 380V±10%;Three phase five wire;

2. Frequency: 50HZ±1HZ;Capacitance: ≥50kVA;Resistance: 0.3 Ω or less

3. The voltage range of the photographic tube is 40~125kV (or 150KV),1KV Step;Tube voltage range 10~640mA;MA accuracy ≤±10%

4. Exposure time range: 1-10000ms;MAs range 0.1-640MAS;MA accuracy ≤± (5%+ 0.2mas)

5.APR storage capacity: 2400 data

6. Auxiliary output power: 24VDC 300mA 220VAC 5A

2. X-ray tube assembly

30.50KW (20.40KW) /125KV (or 150KV);Bifocal 1.0/2.0;Anode heat capacity 140KJ

3. Electric beam limiter

1. Maximum exposure field: 440mm×440mm (SID=100cm);

2. Average luminance of light field: & GT;160 lux.

3. Lighting degree: & GT;4-1.Bulb: 24V/150W;

4. Single lighting time of the field lamp: 30S;Focal point – Mounting surface distance mm (adjustable as required) : 60, intrinsic filtration (75kV) : 1mmAl

4. Sickle arm frame

The upper and lower stroke of the arm is 1200mm±20mm

The lowest position of the arm is 480mm±20mm

Angle of rotation of arm bending is 0°~90°

The rotation range of the plate is -45°~+45

SID 1000 mm to 1800 mm

5. Digital plate detector

1. Type: amorphous silicon + cesium iodide;

2. Imaging size: 17″×17″;

3. Spatial resolution: 3.6lp/mm;

4. Gray level detection (A/D bit number) : 16 bit;Data interface: Gigabit Ethernet;Full image acquisition time: ≤3s

(Specifications are subject to change without prior notice)

6. Mobile photography flat bed

1. Bed surface size: length X width X height 2020mmX800mmX690mm

2. Bed surface material (optional) : density plate/carbon fiber/plexiglass