Newheek manufacture X-ray UC arms

HomeBlog ›Newheek’s sickle arm DRX machine

Newheek’s sickle arm DRX machine

Lillian 5月 18, 2021

The NKX-502 sickle arm DRX machine produced by our Newheek is mainly used for the photographic inspection of the human chest, limbs, pelvis and lumbar spine.
Product advantages of sickle arm DRX machine:
1. Microcomputer control, LCD display, easy operation.
2. Newly designed high frequency and high voltage generator
3. The exposure conditions are stable and accurate, reducing the radiation dose while reducing the generation of soft rays, effectively protecting patients and doctors.
4. Simple and convenient body position display, according to the selected patient’s body shape and location, the exposure parameters can be automatically set, and can be saved and corrected. New sickle arm design
5. Accurate rotation angle and multi-angle photography to meet clinical needs.
6. Reassuring safety features
The fault self-diagnosis function can quickly and accurately judge the fault status, and can automatically protect, display the fault code, accurate, convenient and timely.
7. Using digital flat panel detector, stable performance, greatly reducing X-ray dose
The main configuration and parameters of the sickle arm DRX machine:
1. X-ray high frequency and high voltage generator
2. Power supply voltage: 380V±10%; three-phase five-wire;
Frequency: 50HZ±1HZ; Capacitance: ≥50kVA; Internal resistance: ≤0.3Ω
3. Photography conditions Photography tube voltage range 40~125kV (or 150KV), 1KV step; tube voltage range 10~640mA; mA accuracy ≤±10%
4. Exposure time range: 1-10000ms; mAs range 0.1-640mAs; mA accuracy≤±(5%+0.2mAs)
5. APR storage capacity: 2400 data
6. Auxiliary output power: 24VDC 300mA 220VAC 5A
7. X-ray tube assembly
30.50KW (20.40KW)/125KV (or 150KV); dual focus 1.0/2.0; anode heat capacity 140KJ
8. Electric beam limiter
Maximum irradiation field: 440mm×440mm (SID=100cm);
Average brightness of light field: >160lux;
Illumination ratio: >4:1; Bulb: 24V/150W;
Single lighting time of light field lamp: 30S; distance between focus and installation surface mm (adjustable as required): 60, inherent filter (75kV): 1mmAl
10. Sickle arm frame
Bending arm up and down stroke 1200mm±20mm
The lowest position of the bending arm 480mm±20mm
Bending arm rotation angle 0°~90°
Plate rotation range -45°~+45
SID stroke 1000mm~1800mm
11. Digital flat panel detector
Type: amorphous silicon + cesium iodide;
Image size: 17″×17″;
Spatial resolution: 3.6lp/mm;
Detection gray level (A/D bit number): 16 bit; Data interface: Gigabit Ethernet; Holographic acquisition time: ≤3s
(Specifications are subject to change without notice)
12. Mobile photography flat bed
Bed size: length X width X height 2020mmX800mmX690mm
Bed surface material (optional): MDF/carbon fiber/plexiglass
If you also need a sickle arm DRX machine, please contact us.

U-arm


(+86) 18953679166
service@newheek.com